For laying on the ground, in the ground, concrete, in closed rooms, cable ducts, in power plants and in industry, in city networks where mechanical damage is not expected, and where the cables are not exposed to mechanical stress - For powering distant objects of a permanent or temporary nature.
POWER CABLES
N2XH
Halogen-free, heavy-burning power cable with network polyethylene insulation and sheath of thermoplastic halogen-free mass (0.6/1kV), type N2XH (HD 604 S1 P5-G). Rated voltage: 0.6/1kV Test voltage: 4000V Construction: - Conductor: Wire, made of copper, class 1 - Insulation: Cross-linked PE, XLPE type X11 - Filling: HFFR – halogen-free polymer mixture - Sheath: HFFR polymer mixture type HM4 Place and area of use: For fixed laying indoors, in the air and in concrete, but not for direct laying in water and earth, it is used in places where there is a large concentration of people, as well as in all locations where the degree of protection against fire and the consequences of fire is increased for human life and equipment (hotels, tunnels, subways, solitaires, hospitals, schools, airports, department stores, etc.), and in factory connection halls, where good properties in case of fire are necessary and without any emission of poisonous and corrosive gases (HCl). Operating temperature range: -5°C to +50°C Temperature range during installation: -15°C to +90°C Minimum bending radius: 12ר cable

POWER CABLES
PP00-A (NAYY)
Power (1kV) cables with insulation and PVC sheath, type PP00-A (SRPS N.C5.220) Rated voltage: 0.6/1kV Test voltage: 4kV Construction: - Conductor: Pressed round rope, made of aluminum - Insulation: PVC - Cable core: Insulated conductors are used, the interspace is filled with PVC threads, and the top is covered with thermoplastic tapes. - Sheath: Seamless pipe made of black PVC mass Place and area of use: - For free placement, in the country, concrete, in closed rooms, cable ducts, in power plants and in industry, in city networks where mechanical damage is not expected, and where cables are not exposed to mechanical stress. For powering remote objects of a permanent or temporary nature. - For the needs of the MTK management system in distribution networks, in the case of four-core cables of larger sections, an additional insulated copper conductor of 1.5 mm² or 2.5 mm² is installed in the middle between the cores of the cable.

POWER CABLES
PP00 (NYY)
Power (1kV) cables with insulation and PVC sheath, type PP00 (SRPS N.C5.220) Rated voltage: 0.6/1kV Test voltage: 4kV Construction: - Conductor: Wire or pressed round rope, made of copper - Insulation: PVC - Cable core: Insulated conductors are used, the interspace is filled with PVC threads, and above is a sheath of thermoplastic tapes - Sheath: Seamless pipe made of black PVC mass Place and area of use: - For free placement, in the country, concrete, in closed rooms, cable ducts, in power plants and in industry, in city networks where mechanical damage is not expected, and where cables are not exposed to mechanical stress. - For powering remote objects of a permanent or temporary nature.

POWER CABLES
XP00 (N2XY)
Power cables with XLPE insulation and PVC sheath, type N2XY (XP00) (SRPS HD 603 S1) Rated voltage: 0.6/1kV Test voltage: 4kV / 50Hz Construction: - Conductor: Cu (copper) conductor (RM multiwire) according to standard EN 60228 - Insulation: Cross-linked polyethylene XLPE, type DIX3 according to standard HD 603 S1 - Cable core: Insulated conductors are used, the interspace is filled with PVC threads, and above is a sheath of thermoplastic tapes - Sheath:Black PVC, type DMV6 acc standard HD 603 S1 Place and area of use: - For free laying, in the ground, concrete, in closed rooms, cable ducts, in power plants and in industry, in city networks where mechanical damage is not expected, and where the cables are not exposed to mechanical stress - For powering remote objects of a permanent or temporary character. - For the needs of the MTK management system in distribution networks, with four-core cables of larger sections, an additional insulated copper conductor of 1.5 mm² or 2.5 mm² is installed in the middle between the cores of the cable.

POWER CABLES
XP00-A (NA2XY)
Power cables with XLPE insulation and PVC sheath, type NA2XY (XP00-A)(SRPS HD 603 S1) Rated voltage: 0.6/1kV Test voltage: 4kV / 50Hz Construction: - Conductor: Al (aluminum) conductor (RM multiwire) according to standard EN 60228 - Insulation: Cross-linked polyethylene XLPE, type DIX 3 according to standard HD 603 S1 - Cable core: Insulated conductors are used, the interspace is filled with PVC threads, and the top is covered with thermoplastic tapes. - Sheath: PVC black color, type DMV 6, type DIX 3 according to standard HD 603 S1 Place and area of use: - For free laying, in the ground, concrete, in closed rooms, cable ducts, in power plants and in industry, in city networks where no mechanical damage is expected, and where the cables are not exposed to mechanical stress. - For powering remote objects of a permanent or temporary nature - For the needs of the MTK management system in distribution networks, with four-core cables of larger sections, an additional insulated copper conductor 1.5mm² or 2.5mm² is installed in the middle between the cores of the cable.

Contact